{"id":842,"date":"2026-11-23T05:44:59","date_gmt":"2026-11-23T05:44:59","guid":{"rendered":"https:\/\/zhuoruimech.com\/?p=842"},"modified":"2026-11-23T05:44:59","modified_gmt":"2026-11-23T05:44:59","slug":"hydraulic-cylinder-buffer-seal-interseal-pressure","status":"publish","type":"post","link":"https:\/\/zhuoruimech.com\/de\/hydraulic-cylinder-buffer-seal-interseal-pressure\/","title":{"rendered":"Hydraulic Cylinder Buffer Seals and Interseal Pressure"},"content":{"rendered":"<p><!-- yongjian-guide-2026-11-23 --><\/p>\n<p>A tandem rod sealing system can leak even though the main seal was installed correctly. On cylinders with a buffer ahead of the main seal, the space between the two lips has its own pressure history. Oil that enters that small space must be able to move as the assembly was designed to move it. A buffer that blocks every return path can leave the main seal exposed to sustained pressure after the chamber has already unloaded. Understand the gland as a system before selecting a stronger seal or adding another lip.<\/p>\n<figure class=\"article-photo\"><img decoding=\"async\" src=\"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\" alt=\"Cylinder bodies and end assemblies\" loading=\"lazy\" style=\"max-width:100%;height:auto\"><figcaption>Cylinder bodies and end assemblies.<\/figcaption><\/figure>\n<h2>Separate primary sealing from pressure buffering<\/h2>\n<p>A rod gland has to guide the rod, retain hydraulic fluid and limit contamination as the rod moves across the boundary. Its pressure seal manages dynamic leakage and the oil film on the rod. The wiper protects the space near the gland against dirt and water and can influence film recovery. A buffer is fitted in some designs on the pressure side of the main rod seal to modify the load that the main seal sees. Its profile, material and clearance need to be compatible with the main seal and the actual duty. Its presence alone does not establish a rating.<\/p>\n<p>A short pressure event at the cylinder port may be more severe for a seal than the value shown by a slow mechanical gauge. A switching event, rapid deceleration or load reversal can produce a pressure pulse. Valve timing, restrictions and the cylinder area ratio affect the pressure at the gland. For recurring seal failures, obtain port pressure and movement data from the approved commissioning instrumentation, at a rate suitable for observing the event. A slow shift average does not capture the waveform. Use the actual design and approved maximum pressure envelope for both chambers when evaluating the gland.<\/p>\n<p>Two seals in series can reduce the load at one stage and create a new condition between them. Some profiles are arranged to permit controlled pressure relief toward the cylinder chamber when the load changes. Other gland designs can use an engineered drain or different geometry. The assembly drawing should identify the intended route. Keep the buffer and primary seal part numbers in the purchase record, including any energizers or backup rings. Part names and a nominal diameter do not describe whether the system will relieve interseal pressure in operation.<\/p>\n<h2>Trace pressure during extension, reversal and rest<\/h2>\n<p>Start by drawing three pressure regions. The first is the rod chamber, which can be connected to pressure, an open return or a restricted return depending on the circuit. The second is the space between buffer and primary seal. The third is the outboard region toward the wiper and atmosphere. Add the wiper cavity if the design treats it as a distinct region. Follow what happens during pressurization, long holds, reversal and cooldown. The circuit position that reduces chamber pressure may not instantly reduce pressure in every gland region.<\/p>\n<p>Motion also moves oil. Oil carried on the rod and recovered in the seal stack behaves differently from oil pushed across a joint by static pressure. A seal stack can appear dry in a short hold and show symptoms during repeated longer strokes. An application that changes speed or dwell pattern can therefore expose an existing pressure relief problem. Observe where fluid first becomes visible and whether the symptom grows over cycles. Confirm that apparent gland leakage does not run down from a port or head joint above it. A photograph of the first wet location is more informative than a photo after the whole surface is covered.<\/p>\n<p>A gland with an intermediate drain must be evaluated with its route and pressure condition in mind. Check the approved schematic and actual connections for the designed path, termination and expected behavior. A blocked passage, incorrect plug, return backpressure or changed routing can move pressure where the design did not expect it. Do not add a drain or drill an installed gland based on a generic drawing. Such a change can affect a pressure boundary and requires authorization from the responsible manufacturer or engineer. Use only approved measurement connections and procedures.<\/p>\n<h2>A worked example from motion to pressure relief<\/h2>\n<p>Consider illustrative readings for a cylinder fitted with a gland designed with a dedicated interseal test point. At the beginning of a loaded stroke, the rod chamber is at 120 bar and the intermediate volume is at 8 bar. A brief event takes the chamber to 190 bar and the intermediate pressure to 24 bar. Later, the chamber returns to 6 bar. The monitored intermediate pressure remains near 22 bar through the next movement instead of following the unloading trend expected by the approved design. These numbers are synthetic and do not define a universal acceptable pressure.<\/p>\n<p>The persistence of the intermediate reading now deserves attention. The team can check timestamp alignment, sensor zero, circuit state and port identity, then compare the result with the seal and gland drawing. Did an intended relief feature face the correct side? Did a different kit introduce a second sealing action that changed the return behavior? Is a designated passage actually open to the path shown on the drawing? Repeating the test with the same movement, temperature and sensing method is more informative than changing two seals and checking whether the symptom disappeared. The applicable test method must be approved for the equipment.<\/p>\n<p>Now imagine there is no provision for an intermediate measurement. The team can still record the external leak versus chamber pressure, actuator position and temperature. It can inspect the original rings, groove and approved flow or relief features during safe stripdown. Repeated damage on the outboard seal or a leak that follows a particular reversal suggests a line of investigation. Those observations do not provide a number for pressure in the intermediate space. Report what was measured and what is inferred. That distinction helps prevent an expensive change based on a symptom that could instead originate in the rod track or a damaged sealing edge.<\/p>\n<figure class=\"article-photo\"><img decoding=\"async\" src=\"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/11\/buffer-seal-engineering-example.png\" alt=\"Example of interseal pressure persisting. Illustrative pressure readings from a gland with a designated measurement point.\" loading=\"lazy\" style=\"max-width:100%;height:auto\"><figcaption>Illustrative pressure readings from a gland with a designated measurement point.<\/figcaption><\/figure>\n<h2>Read damaged parts in their installed sequence<\/h2>\n<p>Lay out the removed components in their documented order. Photograph each ring at the angle where it sat if that can be recovered from marks or the disassembly record. Look for an extrusion tail at a gap, localized cutlets, wear concentrated on one side and changes in the wiper profile. Identify where the edges meet the groove and which side normally sees pressure. These observations can distinguish the evidence of a clearance problem from a possible assembly error. After cleaning and discarding the seals, the team loses much of the information needed to connect the symptom to the specific stage.<\/p>\n<p>Measure guide clearance and rod condition with the same care given to elastomer appearance. A worn bearing can let the rod sit off center, enlarge the gap on one side and load the seal lip unevenly. Installing a harder pressure seal without resolving the clearance can move the failure elsewhere. A gouge or corrosion pit across the seal travel can allow oil to pass even when the pressure between stages is normal. Map the damaged track and identify whether it corresponds to usual stroke, an extreme position or a parked rod area. The diagnosis should survive a review of both the hydraulic and mechanical evidence.<\/p>\n<p>Do a compatibility check before ordering. The fluid family, oil temperature, pressure history, speed, clearance and rod surface specification all matter. A buffer that performed satisfactorily at one duty may require review when the system switches fluid, adds faster cycles or changes return conditions. Confirm the designated profile with the seal supplier and the cylinder manufacturer. If a replacement part changes groove dimensions or support, record the drawing revision and test the actual assembly under the agreed procedure. Keep the pressure side marking explicit so the installation can be repeated at the next repair.<\/p>\n<h2>Write the test in terms of machine states<\/h2>\n<ul>\n<li>Establish oil temperature and fluid along with the applicable seal kit revision.<\/li>\n<li>Identify the port and sensor for every pressure plotted and record the time base.<\/li>\n<li>Include the loaded portion of stroke, reversal and the unloaded or idle period relevant to the complaint.<\/li>\n<li>Record position or the motion command with the pressure trace so the event can be located.<\/li>\n<li>Define how external leakage is observed, the agreed criterion and how assembly residue is distinguished.<\/li>\n<li>Ask for the approved disposition for any intermediate pressure finding or relief path fault.<\/li>\n<li>Repeat the relevant measurement after repair and preserve both traces.<\/li>\n<\/ul>\n<p>The factory can exercise selected pressures and movements in a controlled fixture. The installed machine supplies the actual travel, loads and circuit behavior. Compare the two when a cylinder passes a bench test but develops a leak on site. Check whether the test covered the observed reversal, hot running viscosity and dwell. If certain conditions cannot safely be represented at the factory, identify them for the installation test and agree on the observation method before the cylinder leaves the shop.<\/p>\n<h2>Is a buffer seal required on every hydraulic cylinder?<\/h2>\n<p>The manufacturer selects the sealing system against the duty. Some designs handle the fluid, pressure and speed with a suitable primary seal and wiper. Heavier duties with pulses can use a buffer system when the design supports it. Installing an extra ring ahead of an existing lip changes the hydraulic and lubrication behavior of the gland. Confirm the approved arrangement rather than treating the presence of more seals as evidence of a stronger design.<\/p>\n<h2>Can a buffer seal be replaced by the main seal from the same kit?<\/h2>\n<p>Match the part and groove callout. A buffer and main seal may look very similar outside the package. Their operating functions, geometries and relief behavior can be different. A substitution should be reviewed with the manufacturer, including materials, pressure side, clearances and the ability to release or route fluid between stages. Keep the issue open until the correct part and orientation are documented. A pressure hold on a substitute assembly alone is a limited basis for a change that must also work during real motion.<\/p>\n<h2>What can be checked before a cylinder is removed?<\/h2>\n<p>Review the system schematic, safe test points, work sequence and visible leakage location. Collect oil temperature and both port pressures at the relevant event under the approved operating procedure. Confirm if a change in cycle time, valve, oil or maintenance work preceded the issue. Report the first symptom and your evidence. For example, new oil appears at the wiper only after several warm reversals, while the gland joint remains dry. That observation can guide the bench inspection without creating an improvised connection or leaving a pressure chamber unsecured.<\/p>\n<p>At handover, describe exactly which component and behavior changed. If the repair restored the designed relief path, retain a reference trace and the correct kit or drawing designation so the next technician can verify it. If the solution involved the guide or surface instead, keep those measurements with the same trace. The best outcome is a repair record that connects a visible leak to a particular operating state, load path and verified change.<\/p>\n<h2>How should the pressure sensor be selected?<\/h2>\n<p>An intermediate test point may be small compared with the expected pressure change. Verify that the measurement system suits the pressure range, transient response and fluid. The instrument and its connection add volume to the cavity being measured. If that added volume is large compared with the cavity, it can change the observed pressure history. Discuss the method with the design authority and record the hardware, rather than transferring a setup from a large port on the hydraulic power unit. A short or controlled connection can matter to the interpretation of a brief event.<\/p>\n<p>Compare calibration, reference and sample time when using readings from two sensors. The main port and interseal sensor can have different response or zero error, so a slight lead or lag on one trace does not necessarily describe fluid motion. Use a shared time base and show the actual motion or valve state alongside the curves. Keep the diagram of the measurement setup with the plot so the observations can be reviewed after the temporary instrumentation has been removed.<\/p>\n<h2>Technical references and related reading<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Industrial-Cylinder\/cylinder\/Serv\/1110-M3.pdf\">Parker cylinder service bulletin<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/75271.html\">ISO 10100 hydraulic cylinder acceptance tests<\/a><\/li>\n<li><a href=\"https:\/\/zhuoruimech.com\/de\/ursachen-fur-dichtungsversagen-an-hydraulikzylindern\/\">Ausfall der Dichtungen an Hydraulikzylindern: H\u00e4ufige Ursachen und Anzeichen<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.<\/p>","protected":false},"author":1,"featured_media":225,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_yj_news_hero_background_id":0,"_yj_news_eyebrow":"","_yj_news_technical_topic":"","_yj_news_cta_title":"","_yj_news_cta_description":"","_yj_news_cta_label":"","_yj_news_cta_url":"","_yj_news_related_product_ids":[],"_yj_news_related_case_ids":[],"footnotes":""},"categories":[50],"tags":[],"class_list":["post-842","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Hydraulic Cylinder Buffer Seals and Interseal Pressure - Yangzhou Jiangdu Yongjian Co., Ltd<\/title>\n<meta name=\"description\" content=\"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zhuoruimech.com\/de\/hydraulic-cylinder-buffer-seal-interseal-pressure\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hydraulic Cylinder Buffer Seals and Interseal Pressure\" \/>\n<meta property=\"og:description\" content=\"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zhuoruimech.com\/de\/hydraulic-cylinder-buffer-seal-interseal-pressure\/\" \/>\n<meta property=\"og:site_name\" content=\"Yangzhou Jiangdu Yongjian Co., Ltd\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-23T05:44:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jingrunacrylic@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"jingrunacrylic@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/\"},\"author\":{\"name\":\"jingrunacrylic@gmail.com\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"headline\":\"Hydraulic Cylinder Buffer Seals and Interseal Pressure\",\"datePublished\":\"2026-11-23T05:44:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/\"},\"wordCount\":2058,\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\",\"articleSection\":[\"Technical Guides\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/\",\"name\":\"Hydraulic Cylinder Buffer Seals and Interseal Pressure - Yangzhou Jiangdu Yongjian Co., Ltd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\",\"datePublished\":\"2026-11-23T05:44:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"description\":\"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#primaryimage\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\",\"contentUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg\",\"width\":900,\"height\":900},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-buffer-seal-interseal-pressure\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zhuoruimech.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hydraulic Cylinder Buffer Seals and Interseal Pressure\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/\",\"name\":\"Yangzhou Jiangdu Yongjian Co., Ltd\",\"description\":\"Custom hydraulic cylinders, hydraulic systems and hydraulic steel structures engineered for marine, water conservancy, metallurgy, port and heavy-industry projects.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zhuoruimech.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\",\"name\":\"jingrunacrylic@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"caption\":\"jingrunacrylic@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/zhuoruimech.com\"],\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/de\\\/author\\\/jingrunacrylicgmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Hydraulic Cylinder Buffer Seals and Interseal Pressure - Yangzhou Jiangdu Yongjian Co., Ltd","description":"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zhuoruimech.com\/de\/hydraulic-cylinder-buffer-seal-interseal-pressure\/","og_locale":"de_DE","og_type":"article","og_title":"Hydraulic Cylinder Buffer Seals and Interseal Pressure","og_description":"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.","og_url":"https:\/\/zhuoruimech.com\/de\/hydraulic-cylinder-buffer-seal-interseal-pressure\/","og_site_name":"Yangzhou Jiangdu Yongjian Co., Ltd","article_published_time":"2026-11-23T05:44:59+00:00","og_image":[{"width":900,"height":900,"url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg","type":"image\/jpeg"}],"author":"jingrunacrylic@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"jingrunacrylic@gmail.com","Gesch\u00e4tzte Lesezeit":"10\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#article","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/"},"author":{"name":"jingrunacrylic@gmail.com","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"headline":"Hydraulic Cylinder Buffer Seals and Interseal Pressure","datePublished":"2026-11-23T05:44:59+00:00","mainEntityOfPage":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/"},"wordCount":2058,"image":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg","articleSection":["Technical Guides"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/","url":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/","name":"Hydraulic Cylinder Buffer Seals and Interseal Pressure - Yangzhou Jiangdu Yongjian Co., Ltd","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#primaryimage"},"image":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg","datePublished":"2026-11-23T05:44:59+00:00","author":{"@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"description":"Use chamber pressure, interseal pressure and motion data to diagnose problems in a tandem hydraulic cylinder rod seal stack.","breadcrumb":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#primaryimage","url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg","contentUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/offshore-lifting-platform-hydraulic-cylinder-ceramic-rod.jpg","width":900,"height":900},{"@type":"BreadcrumbList","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-buffer-seal-interseal-pressure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zhuoruimech.com\/"},{"@type":"ListItem","position":2,"name":"Hydraulic Cylinder Buffer Seals and Interseal Pressure"}]},{"@type":"WebSite","@id":"https:\/\/zhuoruimech.com\/#website","url":"https:\/\/zhuoruimech.com\/","name":"Yangzhou Jiangdu Yongjian Co., Ltd.","description":"Ma\u00dfgefertigte Hydraulikzylinder, Hydrauliksysteme und Hydraulikstahlkonstruktionen f\u00fcr Projekte in den Bereichen Schifffahrt, Wasserwirtschaft, Metallurgie, Hafenwesen und Schwerindustrie.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zhuoruimech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42","name":"jingrunacrylic@gmail.com","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","caption":"jingrunacrylic@gmail.com"},"sameAs":["https:\/\/zhuoruimech.com"],"url":"https:\/\/zhuoruimech.com\/de\/author\/jingrunacrylicgmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/posts\/842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/comments?post=842"}],"version-history":[{"count":2,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/posts\/842\/revisions"}],"predecessor-version":[{"id":844,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/posts\/842\/revisions\/844"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/media\/225"}],"wp:attachment":[{"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/media?parent=842"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/categories?post=842"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zhuoruimech.com\/de\/wp-json\/wp\/v2\/tags?post=842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}