{"id":469,"date":"2026-09-27T16:54:49","date_gmt":"2026-09-27T16:54:49","guid":{"rendered":"https:\/\/zhuoruimech.com\/?p=469"},"modified":"2026-09-27T16:54:49","modified_gmt":"2026-09-27T16:54:49","slug":"seleccion-del-sensor-de-retroalimentacion-de-posicion-del-cilindro-hidraulico","status":"publish","type":"post","link":"https:\/\/zhuoruimech.com\/es\/hydraulic-cylinder-position-feedback-sensor-selection\/","title":{"rendered":"Retroalimentaci\u00f3n de posici\u00f3n del cilindro hidr\u00e1ulico: elecci\u00f3n de un sensor para el control en bucle cerrado"},"content":{"rendered":"<p>Cuando un cilindro debe detenerse en posiciones intermedias o sincronizarse con otro eje, el controlador necesita una medici\u00f3n fiable del movimiento. Un interruptor b\u00e1sico de fin de carrera solo confirma que se ha alcanzado un punto. La retroalimentaci\u00f3n continua de posici\u00f3n indica d\u00f3nde se encuentra el actuador a lo largo de toda la carrera. La elecci\u00f3n del sensor debe basarse en la precisi\u00f3n de control requerida, la carrera, el entorno y el plan de mantenimiento.<\/p>\n<h2>\u00bfQu\u00e9 es lo que deber\u00eda medir realmente el sensor?<\/h2>\n<p>Un sensor integrado en el cilindro puede medir la posici\u00f3n del pist\u00f3n con respecto al cuerpo del cilindro. En su lugar, un dispositivo externo puede medir el movimiento de un elemento de la m\u00e1quina con respecto a su bastidor. Estos valores no siempre coinciden: el juego de los pasadores, la deflexi\u00f3n estructural y el juego mec\u00e1nico pueden alterar la relaci\u00f3n entre la carrera del cilindro y la posici\u00f3n relevante para el proceso. Indique el punto de control en el plano de la m\u00e1quina antes de solicitar un sensor.<\/p>\n<h2>Opciones habituales de comentarios<\/h2>\n<table>\n<thead>\n<tr>\n<th>Opci\u00f3n<\/th>\n<th>Funci\u00f3n \u00fatil<\/th>\n<th>Comprobaci\u00f3n de integraci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transductor magnetoestrictivo interno<\/td>\n<td>Posici\u00f3n continua del pist\u00f3n sin contacto; disponible como opci\u00f3n integrada en el cilindro<\/td>\n<td>Longitud de carrera, zona muerta, ubicaci\u00f3n del conector, formato de salida y acceso al servicio<\/td>\n<\/tr>\n<tr>\n<td>LVDT<\/td>\n<td>Medici\u00f3n continua del desplazamiento lineal con aplicaci\u00f3n en sistemas de control consolidados<\/td>\n<td>Excitaci\u00f3n o acondicionamiento de la se\u00f1al, instalaci\u00f3n protegida y rango de medici\u00f3n \u00fatil<\/td>\n<\/tr>\n<tr>\n<td>Sensor lineal externo o codificador de cable<\/td>\n<td>Permite observar directamente una pieza de la m\u00e1quina y puede resultar m\u00e1s f\u00e1cil de sustituir<\/td>\n<td>Protecci\u00f3n, alineaci\u00f3n, recorrido del cable, exposici\u00f3n y el efecto del movimiento del bastidor<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Parker documents magnetostrictive probes, LVDTs, linear potentiometers and string potentiometers as possible feedback devices for servo control. This list does not mean that any sensor can be substituted without checking the controller&#8217;s electrical input and the cylinder&#8217;s mechanical design.<\/p>\n<h2>Especificar el rendimiento a nivel del sistema<\/h2>\n<p>La resoluci\u00f3n, la repetibilidad y la precisi\u00f3n describen propiedades diferentes. Pregunta tambi\u00e9n por el tiempo de actualizaci\u00f3n, los efectos de la temperatura, el ruido el\u00e9ctrico y qu\u00e9 ocurre una vez restablecida la alimentaci\u00f3n el\u00e9ctrica. La precisi\u00f3n de la posici\u00f3n en la carga depende del sensor, la v\u00e1lvula, la rigidez hidr\u00e1ulica, la fricci\u00f3n y el sistema de articulaci\u00f3n mec\u00e1nica. Un transductor preciso por s\u00ed solo no puede eliminar el juego ni una respuesta de la v\u00e1lvula mal ajustada.<\/p>\n<h2>Lista de comprobaci\u00f3n para solicitudes de presupuesto<\/h2>\n<ul>\n<li>Carrera, velocidad, tolerancia de parada y repetibilidad requeridas con la carga.<\/li>\n<li>Ubicaci\u00f3n de montaje del sensor, clasificaci\u00f3n de resistencia ambiental, orientaci\u00f3n del conector y recorrido del cable.<\/li>\n<li>Tensi\u00f3n de alimentaci\u00f3n del controlador, protocolo de se\u00f1ales, detecci\u00f3n de fallos y respuesta segura ante la p\u00e9rdida de se\u00f1al de retroalimentaci\u00f3n.<\/li>\n<li>M\u00e9todo de calibraci\u00f3n, acceso para la sustituci\u00f3n y puntos de medici\u00f3n de la FAT.<\/li>\n<\/ul>\n<p>En el caso de varios actuadores, combina esta selecci\u00f3n con nuestro <a href=\"https:\/\/zhuoruimech.com\/es\/sincronizacion-de-dos-cilindros-hidraulicos-mediante-un-divisor-de-caudal-con-retroalimentacion\/\">Gu\u00eda de sincronizaci\u00f3n de cilindros<\/a>. Analiza un sensor integrado al solicitar un <a href=\"https:\/\/zhuoruimech.com\/es\/producto\/cilindros-hidraulicos-para-prensas-a-medida\/\">cilindro de prensa a medida<\/a>.<\/p>\n<p><small>Referencias: <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Industrial-Cylinder\/cylinder\/cat\/english\/0106-7-Industrial-Cylinder-Products\/0106-7_VH.pdf\">Actuador electrohidr\u00e1ulico Parker y sistema de guiado LDT<\/a>; <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Hydraulic-Valve-Division\/hydraulicvalve\/Service-Installation\/Electrohydraulics\/Bul-HY14-1483-M3-23-7030.pdf\">Bolet\u00edn sobre el servocontrol de posici\u00f3n de Parker<\/a>. Portada: ilustraci\u00f3n esquem\u00e1tica original.<\/small><\/p>","protected":false},"excerpt":{"rendered":"<p>Compara los sensores magnetoestrictivos internos, los LVDT y los sistemas de medici\u00f3n de posici\u00f3n externos a la hora de especificar un cilindro hidr\u00e1ulico de bucle cerrado.<\/p>","protected":false},"author":1,"featured_media":468,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_yj_news_hero_background_id":0,"_yj_news_eyebrow":"","_yj_news_technical_topic":"","_yj_news_cta_title":"","_yj_news_cta_description":"","_yj_news_cta_label":"","_yj_news_cta_url":"","_yj_news_related_product_ids":[],"_yj_news_related_case_ids":[],"footnotes":""},"categories":[50],"tags":[],"class_list":["post-469","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control - Yangzhou Jiangdu Yongjian Co., Ltd<\/title>\n<meta name=\"description\" content=\"Compare internal magnetostrictive sensors, LVDTs and external position measurement when specifying a closed-loop hydraulic cylinder.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zhuoruimech.com\/es\/seleccion-del-sensor-de-retroalimentacion-de-posicion-del-cilindro-hidraulico\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control\" \/>\n<meta property=\"og:description\" content=\"Compare internal magnetostrictive sensors, LVDTs and external position measurement when specifying a closed-loop hydraulic cylinder.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zhuoruimech.com\/es\/seleccion-del-sensor-de-retroalimentacion-de-posicion-del-cilindro-hidraulico\/\" \/>\n<meta property=\"og:site_name\" content=\"Yangzhou Jiangdu Yongjian Co., Ltd\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-27T16:54:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jingrunacrylic@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"jingrunacrylic@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/\"},\"author\":{\"name\":\"jingrunacrylic@gmail.com\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"headline\":\"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control\",\"datePublished\":\"2026-09-27T16:54:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/\"},\"wordCount\":399,\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hydraulic-cylinder-position-feedback-sensor-selection.jpg\",\"articleSection\":[\"Technical Guides\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/\",\"name\":\"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control - Yangzhou Jiangdu Yongjian Co., Ltd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hydraulic-cylinder-position-feedback-sensor-selection.jpg\",\"datePublished\":\"2026-09-27T16:54:49+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"description\":\"Compare internal magnetostrictive sensors, LVDTs and external position measurement when specifying a closed-loop hydraulic cylinder.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#primaryimage\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hydraulic-cylinder-position-feedback-sensor-selection.jpg\",\"contentUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/hydraulic-cylinder-position-feedback-sensor-selection.jpg\",\"width\":1200,\"height\":1200,\"caption\":\"Original schematic illustration for Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/hydraulic-cylinder-position-feedback-sensor-selection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zhuoruimech.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/\",\"name\":\"Yangzhou Jiangdu Yongjian Co., Ltd\",\"description\":\"Custom hydraulic cylinders, hydraulic systems and hydraulic steel structures engineered for marine, water conservancy, metallurgy, port and heavy-industry projects.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zhuoruimech.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\",\"name\":\"jingrunacrylic@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"caption\":\"jingrunacrylic@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/zhuoruimech.com\"],\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/es\\\/author\\\/jingrunacrylicgmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Retroalimentaci\u00f3n de posici\u00f3n de cilindros hidr\u00e1ulicos: elecci\u00f3n de un sensor para el control en bucle cerrado - Yangzhou Jiangdu Yongjian Co., Ltd","description":"Compara los sensores magnetoestrictivos internos, los LVDT y los sistemas de medici\u00f3n de posici\u00f3n externos a la hora de especificar un cilindro hidr\u00e1ulico de bucle cerrado.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zhuoruimech.com\/es\/seleccion-del-sensor-de-retroalimentacion-de-posicion-del-cilindro-hidraulico\/","og_locale":"es_ES","og_type":"article","og_title":"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control","og_description":"Compare internal magnetostrictive sensors, LVDTs and external position measurement when specifying a closed-loop hydraulic cylinder.","og_url":"https:\/\/zhuoruimech.com\/es\/seleccion-del-sensor-de-retroalimentacion-de-posicion-del-cilindro-hidraulico\/","og_site_name":"Yangzhou Jiangdu Yongjian Co., Ltd","article_published_time":"2026-09-27T16:54:49+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg","type":"image\/jpeg"}],"author":"jingrunacrylic@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"jingrunacrylic@gmail.com","Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#article","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/"},"author":{"name":"jingrunacrylic@gmail.com","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"headline":"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control","datePublished":"2026-09-27T16:54:49+00:00","mainEntityOfPage":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/"},"wordCount":399,"image":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg","articleSection":["Technical Guides"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/","url":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/","name":"Retroalimentaci\u00f3n de posici\u00f3n de cilindros hidr\u00e1ulicos: elecci\u00f3n de un sensor para el control en bucle cerrado - Yangzhou Jiangdu Yongjian Co., Ltd","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#primaryimage"},"image":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg","datePublished":"2026-09-27T16:54:49+00:00","author":{"@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"description":"Compara los sensores magnetoestrictivos internos, los LVDT y los sistemas de medici\u00f3n de posici\u00f3n externos a la hora de especificar un cilindro hidr\u00e1ulico de bucle cerrado.","breadcrumb":{"@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#primaryimage","url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg","contentUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/09\/hydraulic-cylinder-position-feedback-sensor-selection.jpg","width":1200,"height":1200,"caption":"Original schematic illustration for Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control"},{"@type":"BreadcrumbList","@id":"https:\/\/zhuoruimech.com\/hydraulic-cylinder-position-feedback-sensor-selection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zhuoruimech.com\/"},{"@type":"ListItem","position":2,"name":"Hydraulic Cylinder Position Feedback: Choosing a Sensor for Closed-Loop Control"}]},{"@type":"WebSite","@id":"https:\/\/zhuoruimech.com\/#website","url":"https:\/\/zhuoruimech.com\/","name":"Yangzhou Jiangdu Yongjian S.L.","description":"Cilindros hidr\u00e1ulicos a medida, sistemas hidr\u00e1ulicos y estructuras hidr\u00e1ulicas de acero dise\u00f1adas para proyectos en los sectores mar\u00edtimo, de gesti\u00f3n de recursos h\u00eddricos, metal\u00fargico, portuario y de la industria pesada.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zhuoruimech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42","name":"jingrunacrylic@gmail.com","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","caption":"jingrunacrylic@gmail.com"},"sameAs":["https:\/\/zhuoruimech.com"],"url":"https:\/\/zhuoruimech.com\/es\/author\/jingrunacrylicgmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/posts\/469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/comments?post=469"}],"version-history":[{"count":1,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/posts\/469\/revisions"}],"predecessor-version":[{"id":470,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/posts\/469\/revisions\/470"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/media\/468"}],"wp:attachment":[{"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/media?parent=469"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/categories?post=469"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zhuoruimech.com\/es\/wp-json\/wp\/v2\/tags?post=469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}