{"id":350,"date":"2026-09-24T05:08:34","date_gmt":"2026-09-24T05:08:34","guid":{"rendered":"https:\/\/zhuoruimech.com\/?p=350"},"modified":"2026-09-24T05:08:34","modified_gmt":"2026-09-24T05:08:34","slug":"single-acting-vs-double-acting-hydraulic-cylinders","status":"publish","type":"post","link":"https:\/\/zhuoruimech.com\/ru\/single-acting-vs-double-acting-hydraulic-cylinders\/","title":{"rendered":"Single-Acting vs Double-Acting Hydraulic Cylinders"},"content":{"rendered":"<p>The difference between single-acting and double-acting cylinders is how many directions are powered by hydraulic pressure. A single-acting cylinder uses pressure for one direction and another force for return. A double-acting cylinder uses pressure for both extension and retraction. The best choice depends on how the load must move and how it must be controlled.<\/p>\n<h2>Single-acting: powered one way<\/h2>\n<p>A single-acting cylinder normally has one working port. When oil enters, the piston or plunger moves in its powered direction. A spring, gravity or the applied load moves it back after pressure is released. This arrangement can suit a simple lift or clamp where the return force is available and its timing is acceptable. It should not be assumed that every single-acting cylinder is spring-return; the return mechanism is part of the specification.<\/p>\n<h2>Double-acting: powered both ways<\/h2>\n<p>A double-acting cylinder has a port for each chamber. A directional valve sends oil to one side while allowing oil to leave the other. This gives hydraulic control over extension and retraction, useful when a machine must push and pull or return under a variable load. The rod-end effective area is smaller than the full piston area, so extension and retraction force or speed can differ at the same pressure or flow.<\/p>\n<h2>Compare the complete circuit<\/h2>\n<p>Count the ports, but also inspect the pump, valve, hose routing, load-holding requirements and emergency behavior. A vertical load may need engineered holding and controlled lowering regardless of cylinder type. Consider whether the return force remains available across the entire stroke and whether the machine needs repeatable movement in both directions. Do not disconnect a port or change valve plumbing to make one type behave like the other without an approved circuit design.<\/p>\n<h2>Questions for a supplier<\/h2>\n<p>Provide the load direction, required travel, pressure, return method, speed, mounting and duty cycle. If replacing a unit, send a circuit diagram and photos of both port connections. Yongjian&#8217;s <a href=\"https:\/\/zhuoruimech.com\/ru\/%d1%82%d0%be%d0%b2%d0%b0%d1%80\/%d0%b3%d0%b8%d0%b4%d1%80%d0%b0%d0%b2%d0%bb%d0%b8%d1%87%d0%b5%d1%81%d0%ba%d0%b8%d0%b5-%d1%86%d0%b8%d0%bb%d0%b8%d0%bd%d0%b4%d1%80%d1%8b-%d0%b4%d0%bb%d1%8f-%d0%bf%d1%80%d0%b5%d1%81%d1%81%d0%be%d0%b2\/\">\u0441\u0442\u0440\u0430\u043d\u0438\u0446\u0430 \u00ab\u041f\u0440\u0435\u0441\u0441\u043e\u0432\u044b\u0439 \u0446\u0438\u043b\u0438\u043d\u0434\u0440\u00bb<\/a> illustrates why return motion must be specified, and the <a href=\"https:\/\/zhuoruimech.com\/ru\/%d0%ba%d0%be%d0%bd%d1%82%d1%80%d0%be%d0%bb%d1%8c%d0%bd%d1%8b%d0%b9-%d1%81%d0%bf%d0%b8%d1%81%d0%be%d0%ba-%d0%b4%d0%bb%d1%8f-%d0%b7%d0%b0%d0%bf%d1%80%d0%be%d1%81%d0%b0-%d0%bf%d1%80%d0%b5%d0%b4%d0%bb-2\/\">cylinder RFQ checklist<\/a> lists the remaining inputs.<\/p>\n<p><small>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0441\u043f\u0440\u0430\u0432\u043a\u0430: <a href=\"https:\/\/blog.enerpac.com\/single-acting-vs-double-acting-hydraulic-cylinders\/\">Enerpac single-acting and double-acting cylinder guide<\/a>. \u041f\u0440\u0438\u0432\u0435\u0434\u0435\u043d\u043d\u043e\u0435 \u0432\u044b\u0448\u0435 \u043f\u043e\u044f\u0441\u043d\u0435\u043d\u0438\u0435 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u0435\u043d\u043e \u043d\u0435\u0437\u0430\u0432\u0438\u0441\u0438\u043c\u043e \u0432 \u0446\u0435\u043b\u044f\u0445 \u043e\u0431\u0449\u0435\u0433\u043e \u043e\u0437\u043d\u0430\u043a\u043e\u043c\u043b\u0435\u043d\u0438\u044f; \u043e\u043a\u043e\u043d\u0447\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0440\u0430\u0441\u0447\u0435\u0442\u043d\u044b\u0435 \u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f \u0442\u0440\u0435\u0431\u0443\u044e\u0442 \u0440\u0430\u0441\u0441\u043c\u043e\u0442\u0440\u0435\u043d\u0438\u044f \u0441 \u0443\u0447\u0435\u0442\u043e\u043c \u043a\u043e\u043d\u043a\u0440\u0435\u0442\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0435\u043a\u0442\u0430.<\/small><\/p>","protected":false},"excerpt":{"rendered":"<p>Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.<\/p>","protected":false},"author":1,"featured_media":246,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_yj_news_hero_background_id":0,"_yj_news_eyebrow":"","_yj_news_technical_topic":"","_yj_news_cta_title":"","_yj_news_cta_description":"","_yj_news_cta_label":"","_yj_news_cta_url":"","_yj_news_related_product_ids":[],"_yj_news_related_case_ids":[],"footnotes":""},"categories":[50],"tags":[],"class_list":["post-350","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Single-Acting vs Double-Acting Hydraulic Cylinders - Yangzhou Jiangdu Yongjian Co., Ltd<\/title>\n<meta name=\"description\" content=\"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zhuoruimech.com\/ru\/single-acting-vs-double-acting-hydraulic-cylinders\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single-Acting vs Double-Acting Hydraulic Cylinders\" \/>\n<meta property=\"og:description\" content=\"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zhuoruimech.com\/ru\/single-acting-vs-double-acting-hydraulic-cylinders\/\" \/>\n<meta property=\"og:site_name\" content=\"Yangzhou Jiangdu Yongjian Co., Ltd\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-24T05:08:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"jingrunacrylic@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"jingrunacrylic@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u043c\u0438\u043d\u0443\u0442\u044b\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/\"},\"author\":{\"name\":\"jingrunacrylic@gmail.com\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"headline\":\"Single-Acting vs Double-Acting Hydraulic Cylinders\",\"datePublished\":\"2026-09-24T05:08:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/\"},\"wordCount\":367,\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/hydraulic-cylinder-for-water-gate-hoist.jpg\",\"articleSection\":[\"Technical Guides\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/\",\"name\":\"Single-Acting vs Double-Acting Hydraulic Cylinders - Yangzhou Jiangdu Yongjian Co., Ltd\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/hydraulic-cylinder-for-water-gate-hoist.jpg\",\"datePublished\":\"2026-09-24T05:08:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\"},\"description\":\"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#primaryimage\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/hydraulic-cylinder-for-water-gate-hoist.jpg\",\"contentUrl\":\"https:\\\/\\\/zhuoruimech.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/hydraulic-cylinder-for-water-gate-hoist.jpg\",\"width\":900,\"height\":900},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/single-acting-vs-double-acting-hydraulic-cylinders\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/zhuoruimech.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single-Acting vs Double-Acting Hydraulic Cylinders\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#website\",\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/\",\"name\":\"Yangzhou Jiangdu Yongjian Co., Ltd\",\"description\":\"Custom hydraulic cylinders, hydraulic systems and hydraulic steel structures engineered for marine, water conservancy, metallurgy, port and heavy-industry projects.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/zhuoruimech.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/zhuoruimech.com\\\/#\\\/schema\\\/person\\\/f42514d8e994db13268361b69bcc2f42\",\"name\":\"jingrunacrylic@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g\",\"caption\":\"jingrunacrylic@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/zhuoruimech.com\"],\"url\":\"https:\\\/\\\/zhuoruimech.com\\\/ru\\\/author\\\/jingrunacrylicgmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Single-Acting vs Double-Acting Hydraulic Cylinders - Yangzhou Jiangdu Yongjian Co., Ltd","description":"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/zhuoruimech.com\/ru\/single-acting-vs-double-acting-hydraulic-cylinders\/","og_locale":"ru_RU","og_type":"article","og_title":"Single-Acting vs Double-Acting Hydraulic Cylinders","og_description":"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.","og_url":"https:\/\/zhuoruimech.com\/ru\/single-acting-vs-double-acting-hydraulic-cylinders\/","og_site_name":"Yangzhou Jiangdu Yongjian Co., Ltd","article_published_time":"2026-09-24T05:08:34+00:00","og_image":[{"width":900,"height":900,"url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg","type":"image\/jpeg"}],"author":"jingrunacrylic@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"jingrunacrylic@gmail.com","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"2 \u043c\u0438\u043d\u0443\u0442\u044b"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#article","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/"},"author":{"name":"jingrunacrylic@gmail.com","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"headline":"Single-Acting vs Double-Acting Hydraulic Cylinders","datePublished":"2026-09-24T05:08:34+00:00","mainEntityOfPage":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/"},"wordCount":367,"image":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg","articleSection":["Technical Guides"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/","url":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/","name":"Single-Acting vs Double-Acting Hydraulic Cylinders - Yangzhou Jiangdu Yongjian Co., Ltd","isPartOf":{"@id":"https:\/\/zhuoruimech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#primaryimage"},"image":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#primaryimage"},"thumbnailUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg","datePublished":"2026-09-24T05:08:34+00:00","author":{"@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42"},"description":"Understand how single-acting and double-acting cylinders move, return and connect to a hydraulic circuit, with practical questions for selection.","breadcrumb":{"@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#primaryimage","url":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg","contentUrl":"https:\/\/zhuoruimech.com\/wp-content\/uploads\/2026\/08\/hydraulic-cylinder-for-water-gate-hoist.jpg","width":900,"height":900},{"@type":"BreadcrumbList","@id":"https:\/\/zhuoruimech.com\/single-acting-vs-double-acting-hydraulic-cylinders\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/zhuoruimech.com\/"},{"@type":"ListItem","position":2,"name":"Single-Acting vs Double-Acting Hydraulic Cylinders"}]},{"@type":"WebSite","@id":"https:\/\/zhuoruimech.com\/#website","url":"https:\/\/zhuoruimech.com\/","name":"\u041a\u043e\u043c\u043f\u0430\u043d\u0438\u044f \u00ab\u042f\u043d\u0447\u0436\u043e\u0443 \u0426\u0437\u044f\u043d\u0434\u0443 \u042e\u043d\u0446\u0437\u044f\u043d\u044c\u00bb, \u041e\u041e\u041e","description":"\u0418\u0437\u0433\u043e\u0442\u043e\u0432\u043b\u0435\u043d\u043d\u044b\u0435 \u043f\u043e \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u043e\u043c\u0443 \u0437\u0430\u043a\u0430\u0437\u0443 \u0433\u0438\u0434\u0440\u0430\u0432\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0446\u0438\u043b\u0438\u043d\u0434\u0440\u044b, \u0433\u0438\u0434\u0440\u0430\u0432\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0438 \u0433\u0438\u0434\u0440\u0430\u0432\u043b\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0438, \u0440\u0430\u0437\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u044b\u0435 \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u043e\u0432 \u0432 \u043e\u0431\u043b\u0430\u0441\u0442\u0438 \u0441\u0443\u0434\u043e\u0441\u0442\u0440\u043e\u0435\u043d\u0438\u044f, \u0432\u043e\u0434\u043d\u043e\u0433\u043e \u0445\u043e\u0437\u044f\u0439\u0441\u0442\u0432\u0430, \u043c\u0435\u0442\u0430\u043b\u043b\u0443\u0440\u0433\u0438\u0438, \u043f\u043e\u0440\u0442\u043e\u0432\u043e\u0433\u043e \u0445\u043e\u0437\u044f\u0439\u0441\u0442\u0432\u0430 \u0438 \u0442\u044f\u0436\u0435\u043b\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/zhuoruimech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/zhuoruimech.com\/#\/schema\/person\/f42514d8e994db13268361b69bcc2f42","name":"jingrunacrylic@gmail.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8445618b3e2834fa0c7ae1a03a371ed002e9bf8d2cc1cd989dc4a71bb2b66110?s=96&d=mm&r=g","caption":"jingrunacrylic@gmail.com"},"sameAs":["https:\/\/zhuoruimech.com"],"url":"https:\/\/zhuoruimech.com\/ru\/author\/jingrunacrylicgmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/posts\/350","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/comments?post=350"}],"version-history":[{"count":1,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/posts\/350\/revisions"}],"predecessor-version":[{"id":351,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/posts\/350\/revisions\/351"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/media\/246"}],"wp:attachment":[{"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/media?parent=350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/categories?post=350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zhuoruimech.com\/ru\/wp-json\/wp\/v2\/tags?post=350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}